Features
-
2 Presets ( positions )
-
1 Batch preset ( quantity )
-
3 transistor and 2 relay outputs
-
Choice of various counting modes
-
Multiplier for scaling
-
Programmable switching duration for the 3 outputs
-
Safety against mains failure with data memorized for approximately 10 years
-
High processing speed through the mask-programmed microprocessor used
Description
The GEL 103 counter is a preset and batch counter in a compact DIN 72x72mm housing. It
features an LCD display showing both presets and actual counts. The status of the outputs
is displayed as well. For output 1 and output 2, both relay and transistor output are
available. A third output for batch counting is transistor output only. Several counting
modes are possible. The count input can be interpolated (or multiplied) with a factor of
1, 2 or 4, thus increasing accuracy. An internal multiplier can scale the actual count
input to units, e.g. inches or millimetres. With only four buttons on this counter, it
allows for easy operator training.
Technical Data
|
Power supply ( GEL 103.1 ) |
12 ... 24 VDC -5/+10% |
|
Power supply ( GEL 103.2 ) |
100 ... 240 VAC ±10%, 50/60Hz |
|
Current consumption ( GEL 103.1 ) |
< 250 mA @ 12 ... 24 VDC |
|
Current consumption ( GEL 103.2) |
< 50 mA @ 100 ... 240 VAC |
|
Protection category |
II |
|
General design |
DIN 57411 / VDE 0411 |
|
Resistance to jamming |
Category 3 / IEC 801 |
|
Radio interference suppression |
B / VDE 0871 |
|
Protection type |
IP54 (front panel), IP20 (cabinet) |
|
Operating temperature range |
0°C ... +50°C |
|
Storage temperature range |
-20°C ... +70°C |
|
Dimensions (HxWxD) |
72x72x100 mm |
|
Sensor supply ( GEL 103.1 ) |
Ue-2V, Imax = 60mA |
|
Sensor supply ( GEL 103.2 ) |
24 VDC ±10% |
|
Display |
LCD without background lighting |
|
Data storage |
Approx. 10 years, NV-RAM |
Count Inputs (Input 1, Input 2)
|
Amplitude |
Max. ± 40V, High: >8V, Low: < 2V |
|
Switching edge |
Positive |
|
Pulse shape |
Arbitrary (rectangle 1:1 for max counting frequency) |
|
Input impedance
|
Approx. 5 kOhm |
|
Max. counting frequency |
5 kHz / 30 Hz (bounce free) |
Control Inputs
|
Amplitude |
Max. ± 40V, High >8V, Low <2V |
|
Reset and inhibit |
¹Static |
|
¹Pulse width not attenuated |
¹ >100µsec |
|
¹Pulse width attenuated |
¹ >20msec |
|
Keylock |
²Static |
|
²Pulse width |
²>100msec |
|
Appl |
³Static (non-operative for 200 msec after switching on) |
|
³Pulse width |
³>500µsec |
|
³Reaction time typ. |
³100µsec to positive edge (rectangular signal > 10V, offset <
0.5V) |
Control Outputs, Relay (Out 1, Out 2) Making contact with protective circuit
|
Max. switching voltage |
30 VDC / 250 VAC |
|
Max. switching current |
1 A |
Control Outputs, Transistor (Out 1 ... 3)
|
Max. switching voltage GEL 103.1 |
Ue-2V |
|
Max. switching voltage GEL 103.2 |
24 VDC |
|
Max. switching current |
20 mA, sum of all output currents (transistor and sensor supply) <
90 mA |
Connection Diagram
GEL 103 Dimensions
Order Specifications